Horizontal Rectangular Double & Triple Walled Autoclave

Description
  • The inner/outer chamber, steam jacket and boiler are made of heavy gauge SS with leak proof argon arc welding.
  • The space between the outer chamber and steam jacket is filled with glass wool to minimize thermal losses.
  • Hydraulically tested to withstand 2.5 times the working pressure.
  • Steam boiler is fitted with water level indicator, pressure gauge, low water cut off device and automatic pressure control devices. Fitted with safety valve as a safety device.
  • Drain valve is fitted at the side bottom for easy draining/clearing.
  • This affords a complete safety to the working personnel against explosive opening.
  • Two separate valves are provided for evacuating steam from inner chamber and jacket as and when desired.
  • Sterilization cycle is controlled by single point multiport valve.
  • The chamber discharge line is fitted with a moisture trap to absorb the condensate automatically thus preventing moistening of the loaded material to be sterilized.
  • An automatic vacuum breaker is fitted to all units as a standard accessory in order to break vacuum in case of steam condensation.
  • The flanged immersion type heating element made from a very high grade material provide fast formation of pressure in the system and are protected through a electric low water level cut off device.
  • All sterilizers are provided with triple safety features through a “Piezostate” (automatic pressure control system) and a spring loaded safety valve fitted to the boiler/steam generator.
  • The chamber is fitted with spring loaded safety valve and a dead weight release valve.
  • To work on 220/230 or 440 volts, 3 phase, 50 Hz AC supply.
Model No. MLT-K1 MLT-K2 MLT-K3 MLT-K4 MLT-K5 MLT-K6
Inner Dimension (mm) 450 x 450 x 900 450 x 600 x 900 600 x 600 x 900 600 x 600 x 1200 600 x 900 x 1500 900 x 900 x 1500
Inner Dimension (Inches) 18 x 18 x 36 18 x 24 x 36 24 x 24 x 36 24 x 24 x 48 24 x 36 x 60 36 x 36 x 60
Capacity 180 Litres 240 Litres 320 Litres 430 Litres 810 Litres 1200 Litres
Heater Load 12 KW 12 KW 18 KW 18 KW 24 KW 36 KW
Technical Specification
  • Gasket: made of joint less silicon rubber.
  • Exhaust pressure: manual through the exhaust valve
  • Sterilizing pressure: 1.2 to 1.5 kgf/cm2 (15 to 30 psi) at 121o/134oC.
  • Operating pressure: from 15 psi to 20 psi
  • Pressure gauge: 0.2.1 kgf/cm2 (30 psi)
  • Tubular stand and supporting ring: made of mild steel or stainless steel.
  • Pressure Vessel= Stainless Steel
  • External Wall=SS 202/304 Grade Stainless Steel
  • Top Lid=SS 202/304/316 Grade Stainless Steel
Including
  • Automatic pressure cut off switch
  • Digital temperature indicator cum controller
  • Vacuum breaker
  • Water level indicator
  • Automatic low water cut off switch
  • Moisture trap
Optional
  1. Fully automatic PID purging system
  2. Fully automatic system with HMI PLC based autoclave with data logger.Thermal Printer Vacuum Pump.
  3. Multiport Valve
  4. Automatic self locking system